Add LoRa FEM RX-path LNA control via CLI; restore enabled default
Ported from meshcore-dev/MeshCore#2140 (Quency-D <hj_zzns@163.com>).
The upstream v1.16.0 merge changed the Heltec FEM LNA to disabled by
default (upstream commit 696aae6e). This patch restores the enabled
default for repeater via the new "radio.fem.rxgain" preference
(defaulted to 1), while also making the setting user-configurable
and persisted across reboots.
This commit is contained in:
@@ -123,4 +123,22 @@ void T096Board::powerOff() {
|
||||
|
||||
const char* T096Board::getManufacturerName() const {
|
||||
return "Heltec T096";
|
||||
}
|
||||
}
|
||||
|
||||
bool T096Board::setLoRaFemLnaEnabled(bool enable) {
|
||||
if (!loRaFEMControl.isLnaCanControl()) {
|
||||
return false;
|
||||
}
|
||||
|
||||
loRaFEMControl.setLNAEnable(enable);
|
||||
loRaFEMControl.setRxModeEnable();
|
||||
return true;
|
||||
}
|
||||
|
||||
bool T096Board::canControlLoRaFemLna() const {
|
||||
return loRaFEMControl.isLnaCanControl();
|
||||
}
|
||||
|
||||
bool T096Board::isLoRaFemLnaEnabled() const {
|
||||
return loRaFEMControl.isLNAEnabled();
|
||||
}
|
||||
|
||||
Reference in New Issue